中文  English   

VHP Transfer Chamber

Your Curent Location:Home > Product > VHP Transfer Chamber > VHP sterilization ch

VHP sterilization chamber

Product application:

Applicable to sterilization material/equipment that is not resistant to high temperature in sterile and clean areas, and also applicable to a variety of clean and dry items for transfer in sterilize production such as external package of paacking materials, instrument, external packages of raw material, accessories and environment monitoring equipment.

Use for biological decontamination on the surface of materials to avoid contamination caused by material transferred from non-grade area or low-grade cleaning areas to A/B Grade key areas.


Working Principle:

One-way turbulent flow or laminar flow is formulated from new wind absorbed by Grade-B environment (pre-filtration) or HVAC system through HEPA (H14) filtration in sterilization cabinet and then discharged through air return system after cycling, sterilization and residue removal.

The consumables and instruments that need to be sterilized are transferred into sterilization cabinet through Grade-C area, and then vaporized hydrogen peroxide ions are formulated through dry hydrogen peroxide flash evaporation technology and ionization technology to rapidly and efficiently achieve extermination value of 106 on therinophilic aerobic bacterial spores.

After sterilization and residue removal, consumables and instruments are taken out from exit gate of class-B.


Product Feature:

l The system integrates transfer cabinet body, intelligent operation system, dehumidification module, sterilization module, ventilation module and residue removal module for data online printing.

l All operations are based on HMI intelligent operation including fully automatic operations for enclosed testing, dehumidification, sterilization and residue removal without any human intervention.

l By combining with sterilization module, the air distribution of one-way turbulent flow or laminar follow is dissolved in hydrogen peroxide system to achieve short sterilization period while verifying sterilization period when being fully loaded, to further achieve complete cycle verification for hydrogen peroxide sterilization.


Product parameters:

Type

VHP600

VHP800

VHP1000

Outside dimensions(W*Th*H)

1200*620*185

1350*820*2000

1550*1020*2200

Transfer chamberdimensions:

(W*Th*H)

600*600*600

800*800*800

1000*1000*1000